Sharp JH1600 Inverter Reset

Sharp JH1600 Inverter Soft Reset

For a soft reset, simply hold the “Select” button beneath the screen for five seconds.

 

Sharp JH1600 Inverter Hard Reset

If a soft reset doesn’t work, try a hard reset using the below instructions.

  • Remove the lower cover on the Sharp inverter.
  • Clear the error code list inside the unit:
    1. Press ENT button for 5 seconds. “OFF” is displayed.
    2. Press SEL button the display panel show “EL”.
    3. Press SEL button the display panel show “dAY-P”.
    4. Press SEL button the display panel show “PS”.
    5. Press SEL button the display panel show “d-rSL”.
    6. Press ENT button the display panel show “r_EL”.
      Press ENT button repeat step 5 and step 6 can reset integrated error list.
    7. Press SEL button the display panel show “r_IP”.
      Press ENT button repeat step 5 and step 7 can reset integrated power.
    8. Press SEL button until “OFF” is displayed.
    9. Press ENT button for 5 seconds. The solar power conditioner will start operation again.

If the above instructions didn’t fix your faulty inverter, Service My Solar specialises in fixing faulty solar power systems, so we can help you get your system fully operational again.

 